Lucent Technologies Release 8.2 Server User Manual


 
Configuration 5A: R8csi <—ppp—> R8r (one C-LAN)
<—ethernet—> R8si
155
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
3 C-LAN Administration
Destination Node Name of the far-end node for this channel. This must be a
name entered on the Node Names screen. For ppp
connections, it must match the Destination Node Name
entered on the ppp Data Module screen.
Destination Port A value of 0 allows any available interface channel on the
destination node to be used for this connection. The
Interface Channel number for this connection on the
Switch-2 Processor Channel screen must also be set to 0.
Session - Local The Local and Remote Session numbers can be any value
between 1 and 256 (si model) or 384 (r model), but they
must be consistent between endpoints. For each connection,
the Local Session number on this switch must equal the
Remote Session number on the remote switch and vice
versa.
It is allowed, and sometimes convenient, to use the same
number for the Local and Remote Session numbers. It is
allowed, but not recommended, to use the same Session
numbers for two or more connections.
Session - Remote
Mach ID Destination switch ID identified on the dial plan of the
destination switch.
Processor Channel 13: (ethernet connection to Switch 3)
Enable Set to y.
Appl. Set to dcs for DCS signaling.
Mode Node-1-eth is the “server” for this session. Set node-3 to
“client” (c).
Interface Link This must match the link number assigned on the node-1b
data module screen.
Interface Chan For TCP/IP, interface channel numbers are in the range
5000 – 64500. The value 5003 is recommended for the DCS
connections. This number must match the Destination Port
number on the Switch-2 Processor Channel screen. (Note
that 5003 can be used for the connections to both Switch 2
and 3 because they are on different links).
Destination Node Name of the far-end node for this channel. This must be a
name entered on the Node Names screen. For ppp
connections, it must match the Destination Node Name
entered on the ppp Data Module screen.
Destination Port A value of 0 allows any available interface channel on the
destination node to be used for this connection. The
Interface Channel number on the Switch-3 Processor
Channel screen must also be set to 0.
Field Conditions/Comments
2 of 3