Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
A Screens Reference
Primary Enter the 5-character circuit pack location number for the circuit pack that will
function as the primary synchronization source. The clock circuit pack’s internal
source is the implicit last choice. Only one switch in the network can function as the
primary synchronization source. Only displays when the Stratum field is 4.
The Primary and Secondary synchronization sources (DS1 or BRI trunk facilities)
must be on the same Port Cabinet (that is, PPN, EPN1, or EPN3).
Secondary The system will select automatically the secondary circuit pack if the primary circuit
has a failure. Only displays when the Stratum field is 4.
The Primary and Secondary synchronization sources (DS1 or BRI trunk facilities)
must be on the same Port Cabinet (that is, PPN, EPN1, or EPN3).
Pages 1–X of the screen
Location/Name Identifies the location and name for each DS1 or BRI trunk circuit pack administered
via the DS1 or BRI Trunk Circuit Pack screen. Only displays if the Stratum field is 4.
Valid entries Usage
01 through 44 (G3r) First and second characters are the cabinet number
01 through 03 (G3si)
A through E Third character is the carrier
01 through 20 Fourth and fifth characters are the slot number
blank A blank entry means no external source.
Valid entries Usage
01 through 44 (G3r) First and second characters are the cabinet number
01 through 03 (G3si)
A through E Third character is the carrier
01 through 20 Fourth and fifth characters are the slot number
blank A blank entry means no external source.
Valid entries Usage
Display-only field.