Configuration 5A: R8csi <—ppp—> R8r (one C-LAN)
<—ethernet—> R8si
3 C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
162
> Submit the screen
End
Session - Local The Local and Remote Session numbers can be any value
between 1 and 256 (si model) or 384 (r model), but they
must be consistent between endpoints. For each
connection, the Local Session number on this switch must
equal the Remote Session number on the remote switch
and vice versa.
It is allowed, and sometimes convenient, to use the same
number for the Local and Remote Session numbers. It is
allowed, but not recommended, to use the same Session
numbers for two or more connections.
Session - Remote
Mach ID Destination switch ID identified on the dial plan of the
destination switch.
For Processor Channel 23: (connection to Switch 3 through Switch 1)
Enable Set to y after the link administration is complete.
Appl. Set to dcs for DCS signaling.
Mode Node-2 is the “client” for this session. Set node-3 to
“server” (s).
Interface Link This must match the link number assigned on the node-2
data module screen.
Interface Chan A value of 0 allows any available interface channel to be
used for this connection. The Destination Port number on
the Switch-1 Processor Channel screen must also be set to
0.
Destination Node Name of the far-end node for this channel. This must be a
name entered on the Node Names screen. For ppp
connections, it must match the Destination Node Name
entered on the ppp Data Module screen.
Destination Port This number must match the Interface Channel number
assigned on the Switch-1 Processor Channel screen
Session - Local For each connection, the Local Session number on this
switch must equal the Remote Session number on the
remote switch and vice versa.
Session - Remote
Mach ID Destination switch ID identified on the dial plan of the
destination switch.
Field Conditions/Comments
2 of 2