Lucent Technologies Release 8.2 Server User Manual


 
Configuration 4: R8csi <—ISDN—> R8si Gateway
<—ppp—> R8csi
127
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
3 C-LAN Administration
Switch 1 Task — Assign Link via ppp Data Module to Switch 3
This task administers a ppp data module for the ppp connection to node 3. The data
module associates a link number with a port address, extension number, and node
name for the C-LAN port used for this connection.
Begin
Steps
>
Open Data Module form — enter ad da 5803
[This data module is assigned the extension 5803; you can assign any unused
extension in the dial plan]
> Enter values
add data-module 5803
Page 1 of x
DATA MODULE
Data Extension: 5803 Name: _ppp on link 1 to node-3___ BCC: 2
Type: ppp COS: 1
Port: 01b1115 COR: 1
Link: 1_ TN: 1
Enable Link? n
Node Name: node-1 _____
Subnet Mask: 255.255.255.0
Establish Connection: y
DESTINATION
Digits: 792801_________
Node Name: node-3____
_____
CHAP? n
Field Conditions/Comments
Type: This indicates the data-module type for this connection.
Port: In this example, the C-LAN circuit pack is in slot 01b11; the ppp
connection is through port 15.
Link: The link number must be in the range 1 – 25 (for R8si), not
previously assigned on this switch.
Enable
Link?
If you need to add an IP route that uses this node as a gateway,
this field must be set to
y before adding the IP route. Otherwise
leave this field set to
n until the link administration is complete;
that is, until after all data modules and the processor channels are
assigned, then set to
y.
Name: Information-only; appears in list generated by the “list data
module” command.
1 of 2