Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs)
<—ethernet—> R8si
175
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
3 C-LAN Administration
Switch 1 Task — Assign Link via ppp Data Module to Switch 2
This task administers a ppp data module on Switch 1 for the ppp connection to Switch
2. The data module associates a link number with a port address, extension number,
and node name for the C-LAN port used for this connection.
Begin
Steps
>
Open Data Module form — enter ad da 2010
> Enter values
add data-module 2010
Page 1 of x
DATA MODULE
Data Extension: 2010 Name: _ppp on link 1 to node 2___ BCC: 2
Type: ppp COS: 1
Port: 01c0709 COR: 1
Link: 1_ TN: 1
Enable Link? n
Node Name: node-1a-ppp _
Subnet Mask: 255.255.255.0
Establish Connection: y
DESTINATION
Digits: 8993020_________
Node Name: node-2_____
_____
CHAP? n
Field Conditions/Comments
Type: This indicates the data-module type for this link.
Port: In this example, the C-LAN(a) circuit pack is in slot 01c07; the
ppp connection is through port 09.
Link: The link number must be in the range 1 – 33 (for R8r), not
previously assigned on this switch.
Enable Link? If you need to add an IP route that uses this node as a gateway,
this field must be set to
y before adding the IP route. Otherwise
leave this field set to
n until the link administration is complete;
that is, until after all data modules and the processor channels are
assigned, then set to
y.
Name: Information-only; appears in list generated by the “list data
module” command.
BCC: Bearer Capability Class. This is a display-only field.
1 of 2