Networking Screens A Screens Reference
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
274
Appl. Identifies the switch application used on this link.
Gtwy To Used for gtwy-tcp applications only. Identifies the processor channel that this
processor channel is serving as a gateway to.
Mode Identifies whether the IP session is passive (client) or active (server).
Valid entries Usage
audix, dcs, fp-mwi, gateway,
gtwy-tcp, mis, msaamwl,
msaclk, msahlwc, msallwc,
msamcs, qsig-mwi, and blank
The gateway application is used for conversion
between ISDN and either TCP/IP or BX.25.
The gtwy-tcp application is used for
conversion between BX.25 and TCP/IP.
These application types are used on the
gateway switch only.
Valid entries Usage
1-128 (csi model)
1-256 (si model)
1-384 (r model)
Two processor channels on the gateway switch are needed
to set up a gtwy-tcp gateway, which converts between
X.25 and TCP/IP protocols. For each of the two gtwy-tcp
processor channels, the Gtwy To field points to the other
gtwy-tcp processor channel.
For example, if processor channels 5 and 17 are used for a
gtwy-tcp gateway, Gtwy To for processor channel 5
would be set to 17 and Gtwy To for processor channel 17
would be set to 5.
Valid
entries
Usage
c (client)
s (server)
blank
This field must be blank if the type of interface link is x.25 (r model)
or procr-intf (si model). This field cannot be blank if the type of
interface link is ethernet or ppp.
Set the Mode to s for ppp or ethernet connections to CMS. Set
opposite values (c<-->s) on the endpoints for ppp or ethernet
connections between switches or between a switch and Intuity
AUDIX.