Configuration 3: R8si<—x.25 —> R8r Gateway
<—ethernet—> R8si
3 C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
122
> Submit the screen the screen
End
Destination Port The Destination Port number must match the Interface
Channel number for this connection on the Switch-1
Processor Channel screen.
Session - Local The Local and Remote Session numbers can be any value
between 1 and 256 (si model) or 384 (r model), but they
must be consistent between endpoints. For each
connection, the Local Session number on this switch must
equal the Remote Session number on the remote switch
and vice versa.
It is allowed, and sometimes convenient, to use the same
number for the Local and Remote Session numbers. It is
allowed, but not recommended, to use the same Session
numbers for two or more connections.
Session - Remote
Mach ID Destination switch ID identified on the dial plan of the
destination switch.
Processor Channel 32: (connection to Switch 1 for gateway to Switch 2)
Enable Set to y.
Appl. Set to dcs for DCS signaling.
Mode Node-3 is the “client” for this session. Set node-1 to
“server” (s).
Interface Link This must match the link number assigned on the node-3
data module screen.
Interface Chan A value of 0 allows any available interface channel to be
used for this connection. This number must match the
Destination Port number on the Switch-1 Processor
Channel screen.
Destination Node Name of the far-end node for this channel. This must be a
name entered on the Node Names screen.
Destination Port The Destination Port number must match the Interface
Channel number for this connection on the Switch-1
Processor Channel screen.
Session - Local For each connection, the Local Session number on this
switch must equal the Remote Session number on the
remote switch and vice versa.
Session - Remote
Mach ID Destination switch ID identified on the dial plan of the
destination switch.
Field Conditions/Comments
2 of 2