Configuration 3: R8si<—x.25 —> R8r Gateway
<—ethernet—> R8si
3 C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
102
Switch 1 Task — Assign pdm Data Module
This task administers a pdm data module for the connection between the PGATE
board and the DS1 board for the connection to node-2. The data module associates a
link number with a port address and extension number for the PGATE port used for
this connection.
Begin
Steps
> Open the Data Module form — enter a da n
> Enter values
add data-module next Page 1 of 2
Data Module
Data Extension: 30 Name: pdm on port 1c0102 BCC:
Type: pdm_________ COS: 1 Remote Loop-Around Test? n
Port: 01C0102 COR: 1 Secondary data module? n
ITC: restricted__ TN: 1 Connected to: dte
ABBREVIATED DIALING
List1:
SPECIAL DIALING OPTION:
ASSIGNED MEMBER (Station with a data extension button for this data module)
Ext Name
1: 1002
station name
Field Conditions/Comments
Type: This indicates the data-module type for this connection.
Port: This example means that the PGATE circuit pack is in
slot 01c01 and link 5 uses port 02.
ITC: Enter restricted. (unrestricted is used only for
wideband transmission.)
Name: Information-only; appears in list generated by the “list
data module” command.
COS:
The values for these fields will be specified by the
system administrator.
COR:
TN:
Remote Loop-Around
Test?
Set to
n unless testing.
1 of 2