288
Far-end Listen Port
.
IRQ Required?
.
Calls Share IP signaling connection?
.
Bypass if IP Threshold Exceeded?
.
Internetworking Message
Specifies whether the system sends alerting or progress if an incoming trunk call is
routed to a non-ISDN trunk group (for example, CO or tie). This field is
administerable on a per-port basis.
.
Valid entries Usage
blank or
0–65535
Optional. If entered, the same number as entered in
the Near-end Listen Port field is recommended; if not
left blank, this number must match the number
entered in the Near-end Listen Port field on the
signaling group form for the far-end switch.
Valid entries Usage
y
n (default)
Leave the default (n) if the far-end switch is a
DEFINITY ECS. Set to y only if the far-end switch is
a non-DEFINITY switch and requires a location
request (to obtain a signaling address) in its signaling
protocol.
Valid entries Usage
y
n (default)
Enter y for inter-DEFINITY connections. Otherwise,
leave the default (n).
Valid entries Usage
y
n (default)
Set to y to automatically remove from service trunks
assigned to this signaling group when IP transport
performance falls below limits administered on the
Maintenance-Related System Parameters (sys par
maint) screen.
Valid entries Usage
PROGress (default)
ALERTing