Other Networking-Related DEFINITY Screens
295
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
A Screens Reference
Data Module - type netcon
Common Fields See Common Data Module Fields (256) for descriptions of fields on this screen that
are not listed below.
Physical Channel Identifies the number of the Network Control/Packet Interface data channel
(identified as a netcon data channel). This field appears only the si models.
Maintenance Extension The extension used to perform maintenance functions on the standby physical
channel in a duplicated system. This is the extension specified on the dial plan. The
standby remote loop around tests fail if this field is not administered.
Maximum Bit Rate Identifies the maximum allowable bit rate for the modem. Displays only if the Modem
field is
y.
Page 1 of 1
DATA MODULE
Data Extension: ____ Name: BCC: _
Type: netcon COS: _ Maintenance Extension: ____
Physical Channel: __ COR: _
Name: ______________ TN: _ Maximum Bit Rate: ____
ITC: restricted
ABBREVIATED DIALING
List1: _______________
SPECIAL DIALING OPTION: ____
HOT LINE DESTINATION
Abbreviated Dialing Dial Code (From above list): _
ASSIGNED MEMBER (Station with a data extension button for this data module)
Ext Name
1.
Valid Value Usage
1 to 8
Valid entries Usage
300, 1200, 2400, 4800,
9600, 14400, 19200, and
28800
default is 9600