Lucent Technologies Release 8.2 Server User Manual


 
Configuration 5A: R8csi <—ppp—> R8r (one C-LAN)
<—ethernet—> R8si
167
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000 CID: 77730
3 C-LAN Administration
Switch 3 Task — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module on Switch 3 for the ethernet
connection. The data module associates a link number with a port address, extension
number, and node name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter a da n
> Enter values
> Submit the screen
End
add data next Page 1 of X
DATA MODULE
Data Extension: 3901 Name: ethernet on link 1
BCC: 2
Type: ethernet
Port: 01a0517_
Link: 1
Network uses 1’s for broadcast addresses? y
Field Conditions/Comments
Type: This indicates the data-module type for this link.
Port: Ethernet connections must be assigned to port 17 on the C-LAN
circuit pack.
Link: The link number must be in the range 1 – 25, not previously
assigned on this switch.
Name: Information-only; appears in “list data module” list.
Network
uses 1’s for
broadcast
addresses?
Leave the default (y) if the private network contains only
DEFINITY switches and adjuncts. Set to n only if the network
includes non-DEFINITY switches that use the 0’s method of
forming broadcast addresses. See Appendix A, “Data Module -
type ethernet” for more information about this field.