Lucent Technologies Release 8.2 Server User Manual


 
Switch-Node 3 Administration 4 Networking Example
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
228
Switch-Node 3 Administration
This section displays the filled-in screens for the administration of Switch Node 3.
DS1 Circuit Packs
Dial Plan
add ds1 1a11 Page 1 of 2
DS1 CIRCUIT PACK
Location: 01a11
Name: Switch 3 to Switch 1
Bit Rate: 1.544 Line Coding: b8zs
Line Compensation: 1
Framing Mode: esf
Signaling Mode: isdn-pri
Interface Companding: mulaw
Idle Code: 11111111
DMI-BOS? n
Slip Detection? n Near-end CSU Type: other
change dialplan
DIAL PLAN RECORD
Local Node Number: 3
ETA Node Number:
Uniform Dialing Plan: 4-digit ETA Routing Pattern:
UDP Extension Search Order: local-extensions-first
FIRST DIGIT TABLE
First Length
Digit - 1 - - 2 - - 3 - - 4 - - 5 - - 6 -
1: extension
2: extension
3: extension
4: extension
5:
6:
7: dac
8: fac
9: fac
0: attd
*: dac