Configuring the Execution Environment
foverd.ipLocalPortB To define the secondary local port number used for IP
communication, enter a unique number, keeping the following in
mind:
Typically, if Type is socket, set this value to 1053.
If you have two Cisco PGW 2200 Softswitch hosts in a
switchover configuration, enter this value in the
foverd.ipPeerPortB field in the XECfgParm.dat file on the
secondary host.
Caution The value of foverd.ipLocalPortB must be unique for
every host on the network. Otherwise, active and
standby hosts cannot communicate properly. In the
instance discussed here, no other machine on the
network can have foverd.ipLocalPortB set to 1053. If
that happens, the active and standby hosts cannot
perform proper switchover.
foverd.ipPeerPortB To define the secondary local port number used for IP
communication, enter a unique number, keeping the following in
mind:
Typically, if Type is socket, set this value to 1054.
If you have two Cisco PGW 2200 Softswitch hosts in a
switchover configuration, enter this value in the
foverd.ipLocalPortB field in the XECfgParm.dat file on the
secondary host.
Caution The value of foverd.ipPeerPortB must be unique for
every host on the network. Otherwise, master and slave
hosts cannot communicate properly. In the instance
discussed here, no other machine on the network can
have foverd.ipPeerPortB set to 1054. If that happens, the
master and slave hosts cannot perform proper
switchover.
foverd.conn3Type To set the connection type for connection number 3, enter serial or
socket.
Note Typically, set this value to serial.
foverd.conn3Addr To specify the address of the peer system, enter a location; for
example, /dev/term/a.
If your configuration does not use connection number 3, enter
/dev/null (default).
Note If your configuration uses an 8-port connector as a serial
connection for switchover, you must modify the read-write
permissions for the connection.
Parameter Modification