Sample Configured XECfgParm.dat Files for Cisco PGW 2200 Softswitch Release 9.8(1)
#----------------------
cdrDmpr.openCDR = true
cdrDmpr.seqFile = ../var/.cdr.seq
#------------------------------------
# Alarms/Measurements dumper (amDmpr)
#------------------------------------
#-------------
# ioChanMgr
#-------------
# Internal debug - only use this for low-level IOS debug
# This is bitmapped hex value:
# 1 - Managed Object tracing
# 2 - Simulation of streams devices from /dev to ../dev for
# unit testing.
ioChanMgr.trace = 0x0
# These timers are in millisecs
# NOTE: alarms are sent autonomously as they occur, alarmTimer is outdated
# and should be set to zero. If IPCTimer is 0, then hard-coded value will be
# used. Only for problems with the hard-code should this value be changed.
ioChanMgr.alarmTimer = 0
ioChanMgr.statTimer = 30000
ioChanMgr.IPCTimer = 0
#Channel manager parameters for IPC flow control.
# evtTimer(msec.) - Frequency at which the queue is scanned for Msgs.
# hbTimer(msec.) - Heart-beat timer, Not yet implemented.
# statDiscardThreshold - Size of Control Queue that triggers discarding
# all the queued stat events.
# sendThreshold - Max. Number of Events from the Queue sent at a time.
# IPCsendThreshold - Max. Number of RSIPs from the Queue sent at a time.
ioChanMgr.evtTimer = 100
ioChanMgr.hbTimer = 1000
ioChanMgr.statDiscardThreshold = 40
ioChanMgr.sendThreshold = 10
ioChanMgr.IPCsendThreshold = 0
#Channel manager parameters for SCC switchover on MGX
# Both sessionPauseTimer and resumeAckTimer are in seconds.
ioChanMgr.sessionPauseTimer = 8
ioChanMgr.resumeAckTimer = 1
# Channel manager parameter for amount of time that PDUs are held back
# in IOCC after recovery of SS7 sigserv, before forwarding to engine
ioChanMgr.IDUHoldTimer = 500
#-----------
# ioChanCtl
#-----------
ioChanCtl.DPNSSTestFrames = true
ioChanCtl.xgcpMultiThread = true # enable threading for the IP receive loop in MGCP
ioChanCtl.ituIsNewZealand = false # for New Zealand MTP3 set appropriate ITU
properties
#-----------
# SIP
#-----------
SIP.maxConnection = 200 # Maximum TCP connextions supported by PGW
simultaneourly
SIP.connIdlePeriod = 43200 # How long one TCP connection coulbe be stay in idle
state in second. 0 means PGW never close idle connection