7.5.1.0 Introduced on the C-Series.
snmp-server enable traps
Enable SNMP traps.
Z9500
Syntax
snmp-server enable traps [notification-type] [notification-
option]
To disable traps, use the no snmp-server enable traps [notification-
type
] [notification-option] command.
Parameters
notification-
type
Enter the type of notification from the following list:
bgp — Enable notification of changes in the BGP process.
config — Enable notification of changes to startup or
running configuration.
ecfm — Enable notification of changes to ECFM.
ecmp — Enable notification of traffic imbalance in ECMP
or a link bundle.
entity —Enable notification of Entity Management
Information Base (MIB) changes.
envmon — Enable notification when an environmental
threshold is exceeded.
hg-lbm — Enable notification of hiGig link-bundle state
changes.
isis — Enable notification of IS-IS adjacency state
changes.
lacp — Enable notification of LACP state changes.
snmp — Enable SNMP notifications defined in RFC 1157.
stp — Enable notification of a state change in the
spanning tree protocol (RFC 1493).
vlt — Enable notification of VLT state changes.
vrrp —Enable notification of a state change in a VRRP
group.
xstp — Enable notification of a state change in MSTP
(802.1s), RSTP (802.1w), and PVST+.
notification-
option
For the envmon notification-type, enter one of the following
optional parameters:
cam-utilization
fan
supply
Simple Network Management Protocol (SNMP) and Syslog