Example: After
offline
diagnostics are
run on a line
card
Dell# show diag linecard 0 summary
Diag status of linecard member 0:
---------------------------------------------------------------
-----------
linecard is currently offline.
linecard level0 diag issued at Wed Jan 08, 2014 04:39:58
AM.
Current diag status : Card diags are done.
Duration of execution (Total) : 0 min 31 sec.
Diagnostic test results located: flash:/TestReport-
LP-0.txt
Last notification received at Wed Jan 08, 2014 04:40:29 AM
Last notification message : Level0 diag done.
---------------------------------------------------------------
-----------
DELL DIAGNOSTIC [0]
PPID -- NA
PPID Rev -- NA
Service Tag -- NA
Part Number -- NA
Part Number Revision -- NA
SW Version -- 9-2(1-509)
Available free memory: 2,635,960,320 bytes
--------- Group Test Statistics ---------
Total : 11
Passed : 9
Failed : 2
Elapsed time : 00H:00M:18S
Stop reason : after completion
------ Failed tests (level, times) ------
i2cTest (0, 1)
qsfpOpticsTest (0, 1)
---------------------------------------------------------------
----
Dell# show diag linecard 0 detail
Diag status of linecard member 0:
---------------------------------------------------------------
-----------
linecard is currently offline.
linecard level0 diag issued at Wed Jan 08, 2014 04:39:58
AM.
Current diag status : Card diags are done.
Duration of execution (Total) : 0 min 31 sec.
Diagnostic test results located: flash:/TestReport-
LP-0.txt
Last notification received at Wed Jan 08, 2014 04:40:29 AM
Last notification message : Level0 diag done.
---------------------------------------------------------------
654
Debugging and Diagnostics