To remove an SNMPv3 view, use the no snmp-server view view-name oid-
tree {included | excluded} command.
Parameters
view-name Enter the name of the view (not to exceed 20 characters).
oid-tree Enter the OID sub tree for the view (not to exceed 20
characters).
included (OPTIONAL) Enter the keyword included to include the MIB
family in the view.
excluded (OPTIONAL) Enter the keyword excluded to exclude the
MIB family in the view.
Defaults none
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
Usage
Information
The oid-tree variable is a full sub-tree starting from 1.3.6 and cannot specify the
name of a sub-tree or a MIB. The following Example configures a view named
rview that allows access to all objects under 1.3.6.1.
Example
Dell# conf
Dell#(conf) snmp-server view rview 1.3.6.1 included
Related
Commands
show running-config snmp — displays the SNMP running configuration.
Simple Network Management Protocol (SNMP) and Syslog
1727