Dell 9.8(0.0) Switch User Manual


  Open as PDF
of 1905
 
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 Introduced.
Usage
Information
This command applies to both IPv4 and IPv6 CAM Profiles, but is best used when
verifying QoS optimization for IPv6 ACLs.
QoS Optimization for IPv6 ACLs does not impact the CAM usage for applying a
policy on a single (or the first of several) interfaces. It is most useful when a policy
is applied across multiple interfaces; it can reduce the impact to CAM usage across
subsequent interfaces.
The following describes the test cam-usage command shown in the following
example.
Term Explanation
Linecard Lists the line cards that are checked. Entering all displays
the status for line cards in the chassis.
Portpipe Lists the port pipes (port sets) that are checked. Entering
all displays the status for all line cards and port pipes in the
chassis.
CAM Partition Shows the CAM profile of the CAM.
Available CAM Identifies the amount of CAM space remaining for that
profile.
Estimated CAM
per Port
Estimates the amount of CAM space the listed policy will
require.
Status Indicates whether or not the policy will be allowed in the
CAM.
Example
Dell# test cam-usage service-policy input pcam linecard all
linecard | Portpipe | CAM Partition | Available CAM |
Estimated CAM per Port | Status
---------------------------------------------------------------
---------------------------
0 | 0 | IPv4Flow | 408
| 1 | Allowed (408)
0 | 1 | IPv4Flow | 408
| 1 | Allowed (408)
0 | 2 | IPv4Flow | 408
586
Content Addressable Memory (CAM)