Dell 9.8(0.0) Switch User Manual


  Open as PDF
of 1905
 
9:Task(tUsrRoot): [ 36]SS DRV DEBUG: port:28 isfanout:0
10:Task(tUsrRoot): [ 35]SS DRV DEBUG: port:32 isfanout:0
Usage
Information
This command displays internal software driver information, which may be useful
during troubleshooting switch initialization errors, such as a downed Port-Pipe.
show logging kernellog
Display the kernel log for the specified hardware component.
Z9500
Syntax
show logging kernellog {cp | rp | linecard slot-id}
Parameters
cp Enter the keyword cp to display the kernel log for the
Control Processor on the switch.
rp Enter the keyword cp to display the kernel log for the Route
Processor on the switch.
linecard slot-id Enter the linecard slot-id parameters to specify the
line-card ports for which you want to display the kernel log.
The range of line-card slot IDs is from 0 to 2.
defaults none
Command
Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
Examples
Dell# show logging kernellog cp
00:00:02:326592:AHCI_P_SCTL(0x01ac) 0x00000300
00:00:02:326599:AHCI_P_SERR(0x01b0) 0x00000000
00:00:02:326605:AHCI_P_SACT(0x01b4) 0x00000000
00:00:02:655656:pca9555x3:pca9555_write: iic_smbus_write_byte
failed addr=0x20 cmd_reg=0x8 rv=5
00:00:02:656982:pca9555x3:pca9555_write: iic_smbus_write_byte
failed addr=0x20 cmd_reg=0x9 rv=5
00:00:02:659597:pca9555x3:pca9555_write: iic_smbus_write_byte
1750
Simple Network Management Protocol (SNMP) and Syslog