Maxim DS33R11 Switch User Manual


 
DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
157 of 344
Register Name:
LI.TBCR0
Register Description:
Transmit Byte Count Byte 0
Register Address:
0D0h
Bit # 7 6 5 4 3 2 1 0
Name TBC7 TBC6 TBC5 TBC4 TBC3 TBC2 TBC1 TBC0
Default 0 0 0 0 0 0 0 0
Bits 0 – 7: Transmit Byte Count (TBC[0:7]) – Eight bits of 32 bit value. Register description below.
Register Name:
LI.TBCR1
Register Description:
Transmit Byte Count Byte 1
Register Address:
0D1h
Bit # 7 6 5 4 3 2 1 0
Name
TBC15 TBC14 TBC13 TBC12 TBC11 TBC10 TBC9 TBC8
Default 0 0 0 0 0 0 0 0
Bits 0 – 7: Transmit Byte Count (TBC[15:8]) - Eight bits of 32 bit value. Register description below.
Register Name:
LI.TBCR2
Register Description:
Transmit Byte Count Byte 2
Register Address:
0D2h
Bit # 7 6 5 4 3 2 1 0
Name
TBC23 TBC22 TBC21 TBC20 TBC19 TBC18 TBC17 TBC16
Default 0 0 0 0 0 0 0 0
Bits 0 – 7: Transmit Byte Count (TBC[23:16]) - Eight bits of 32 bit value. Register description below.
Register Name:
LI.TBCR3
Register Description:
Transmit Byte Count Byte 3
Register Address:
0D3h
Bit # 7 6 5 4 3 2 1 0
Name
TBC31 TBC30 TBC29 TBC28 TBC27 TBC26 TBC25 TBC24
Default 0 0 0 0 0 0 0 0
Bits 0 – 7: Transmit Byte Count (TBC[31:24]) – These thirty-two bits indicate the number of packet bytes
inserted in the outgoing data stream.
Register Name:
LI.TMEI
Register Description:
Transmit Manual Error Insertion
Register Address:
0D4h
Bit # 7 6 5 4 3 2 1 0
Name - - - - - - - TMEI
Default 0 0 0 0 0 0 0 0
Bit 0: Transmit Manual Error Insertion (TMEI) A zero to one transition will insert a single error in the Transmit
direction.