DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
227 of 344
Register Name:
TR.INFO5, TR.INFO6
Register Description:
HDLC #1 Information Register
HDLC #2 Information Register
Register Address:
2Eh, 2Fh
Bit # 7 6 5 4 3 2 1 0
Name — — TEMPTY TFULL REMPTY PS2 PS1 PS0
Default 0 0 0 0 0 0 0 0
Bit 5: Transmit FIFO Empty (TEMPTY). A real-time bit that is set high when the FIFO is empty.
Bit 4: Transmit FIFO Full (TFULL). A real-time bit that is set high when the FIFO is full.
Bit 3: Receive FIFO Empty (REMPTY). A real-time bit that is set high when the receive FIFO is empty.
Bits 0 – 2: Receive Packet Status (PS0 to PS2). These are real-time bits indicating the status as of the last read
of the receive FIFO.
PS2 PS1 PS0 Packet Status
0 0 0
In Progress
0 0 1
Packet OK: Packet ended with correct CRC codeword
0 1 0
CRC Error: A closing flag was detected, preceded by a corrupt CRC
codeword
0 1 1
Abort: Packet ended because an abort signal was detected (seven
or more 1s in a row).
1 0 0
Overrun: HDLC controller terminated reception of packet because
receive FIFO is full.
Register Name:
TR.INFO4
Register Description:
HDLC Event Information Register #4
Register Address:
2Dh
Bit # 7 6 5 4 3 2 1 0
Name — — — — H2UDR H2OBT H1UDR H1OBT
Default 0 0 0 0 0 0 0 0
Bit 3: HDLC #2 Transmit FIFO Underrun Event (H2UDR). Set when the transmit FIFO empties out without
having seen the TMEND bit set. An abort is automatically sent. This bit is latched and is cleared when read.
Bit 2: HDLC #2 Opening Byte Event (H2OBT). Set when the next byte available in the receive FIFO is the first
byte of a message.
Bit 1: HDLC #1 Transmit FIFO Underrun Event (H1UDR). Set when the transmit FIFO empties out without
having seen the TMEND bit set. An abort is automatically sent. This bit is latched and is cleared when read.
Bit 0: HDLC #1 Opening Byte Event (H1OBT). Set when the next byte available in the receive FIFO is the first
byte of a message.