Register Name:
TR.BEC1
Register Description:
BERT Error-Count Register 1
Register Address:
E7h
Bit # 7 6 5 4 3 2 1 0
Name EC7 EC6 EC5 EC4 EC3 EC2 EC1 EC0
Default 0 0 0 0 0 0 0 0
Bits 0 – 7: Error Counter Bits 0 to 7 (EC0 to EC7). EC0 is the LSB of the 24-bit counter.
Register Name:
TR.BEC2
Register Description:
BERT Error-Count Register 2
Register Address:
E8h
Bit # 7 6 5 4 3 2 1 0
Name EC15 EC14 EC13 EC12 EC11 EC10 EC9 EC8
Default 0 0 0 0 0 0 0 0
Bits 0 – 7: Error Counter Bits 8 to 15 (EC8 to EC15)
Register Name:
TR.BEC3
Register Description:
BERT Error-Count Register 3
Register Address:
E9h
Bit # 7 6 5 4 3 2 1 0
Name EC23 EC22 EC21 EC20 EC19 EC18 EC17 EC16
Default 0 0 0 0 0 0 0 0
Bits 0 – 7: Error Counter Bits 16 to 23 (EC16 to EC23). EC0 is the MSB of the 24-bit counter.