DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
197 of 344
Register Name:
SU.TxBytesCtr
Register Description:
MAC All Bytes Transmitted Counter
Register Address:
0308h (indirect)
0308h:
Bit # 31 30 29 28 27 26 25 24
Name
TXBYTEC31 TXBYTEC30 TXBYTEC29 TXBYTEC28 TXBYTEC27 TXBYTEC26 TXBYTEC25 TXBYTEC24
Default 0 0 0 0 0 0 0 0
0309h:
Bit # 23 22 21 20 19 18 17 16
Name
TXBYTEC23 TXBYTEC22 TXBYTEC21 TXBYTEC20 TXBYTEC19 TXBYTEC18 TXBYTEC17 TXBYTEC16
Default 0 0 0 0 0 0 0 0
030Ah:
Bit # 15 14 13 12 11 10 09 08
Name
TXBYTEC15 TXBYTEC14 TXBYTEC13 TXBYTEC12 TXBYTEC11 TXBYTEC10 TXBYTEC9 TXBYTEC8
Default 0 0 0 0 0 0 0 0
030Bh:
Bit # 07 06 05 04 03 02 01 00
Name
TXBYTEC7 TXBYTEC6 TXBYTEC5 TXBYTEC4 TXBYTEC3 TXBYTEC2 TXBYTEC1 TXBYTEC0
Default 0 0 0 0 0 0 0 0
Bits 0 - 31: All Bytes Transmitted Counter (TXBYTEC[0:31]) 32 bit value indicating the number of bytes
transmitted. Each time a byte is transmitted, this counter is incremented by 1. This counter resets only upon device
reset, does not saturate, and rolls-over to zero upon reaching the maximum value. The user should ensure that the
measurement period is less than the minimum length of time required for the counter to increment 2^32-1 times at
the maximum data rate. The user should store the value from the beginning of the measurement period for later
calculations, and take into account the possibility of a roll-over to occurring.