NETGEAR GS728TP100NAS Switch User Manual


 
Configuring System Information
79
ProSafe M5300 Switch
4. Click CANCEL to abandon the changes.
5. Click RESET to redisplay the page with the latest status values from the switch.
Field Description
Operation Status Indicates whether NSF is operational on the stack, which may differ from the Admin
Status setting. If a unit that does not support NSF is connected to the stack, then
NSF is disabled on all stack members. When a unit that does not support NSF is
disconnected from the stack and all other units support NSF, and NSF is
administratively enabled, then NSF operation resumes.
Last Startup Reason The type of activation that caused the software to start the last time. The possible
values are:
Power On The switch rebooted, caused by a power cycle or an administrative
“Reload” command.
Administrative Move The administrator issued a command for the stand-by
manager to take over.
Warm Admin Move The administrator issued a command for the backup
manager to take over.
Warm The primary management card restarted due to a failure, and the
system executed a nonstop forwarding failover to a backup management unit.
Auto Cold The system switched from the active manager to the backup
manager and was unable to maintain user data traffic. This is usually caused by
multiple failures occurring close together.
Time Since Last
Restart
Time since the current management card became the active management card. For
the backup management unit, the value is set to 0d 00:00:00.
Restart In Progress Indicates whether a restart is in progress. A restart is not considered complete until
all hardware tables have been fully reconciled.
Warm Restart Ready Indicates whether the initial full checkpoint has finished.
Backup
Configuration Age
Indicates the time since the running configuration was last copied to the backup unit.
The NSF Summary page includes the following non-configurable information: