D-Link DGS-3600 Switch User Manual


 
xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
254
create sflow analyzer_server
switch to be analyzed, and to analyze these datagrams. Users may
specify up to four unique analyzers to receive datagrams, yet the
virtual port used must be unique to each entry.
Parameters <value 1-4> - Enter a value from 1 to 4 to identify the sFlow server
being created here.
owner <name 16> - Enter the owner of the entry made here. The
user that added this sFlow analyzer configures this name.
timeout <sec 1-2000000> - Used to specify the timeout for the
Analyzer server. When the server times out, all sFlow samples and
counter polls associated with this server will be deleted. The user
may set a time between 1 and 2000000 seconds with a default
setting of 400 seconds.
collectoraddress <ipaddr> - The IP address of the sFlow Analyzer
Server. If this field is not specified, the entry will become 0.0.0.0 and
therefore the entry will be inactive. Users must set this field.
collectorport <udp_port_number 1-65535> - The destination UDP
port where sFlow datagrams will be sent. The default setting for this
field is 6343. Only one Analyzer Server address can be set for one
UDP Collector Port.
maxdatagramsize <value 300-1400> - This field will specify the
maximum number of data bytes that can be packaged into a single
sFlow datagram. Users may select a value between 300 and 1400
bytes with a default setting of 1400 bytes.
Restrictions Only administrator-level users can issue this command.
Example usage:
To create the sFlow server:
DGS-3600:4# create sflow analyzer_server 1 owner monitor
Command: create sflow analyzer_server 1 owner monitor
Success.
DGS-3600:4#
config sflow analyzer_server
Purpose Used to configure the analyzer server for the sFlow functions.
Syntax
config sflow analyzer_server <value 1-4> {timeout <sec 1-
2000000 | collectoraddress <ipaddr> | collectorport
<udp_port_number 1-65535> | maxdatagramsize <value 300-
1400>}
Description This command is used to configure the settings for the remote sFlow
Analyzer (collector) that will be used to gather and analyze sFlow
Datagrams that originate from the Switch. Users must have the
proper sFlow software set on the Analyzer in order to receive
datagrams from the switch to be analyzed, and to analyze these
datagrams. Users may specify up to four unique analyzers to receive
datagrams, yet the virtual port used must be unique to each entry.
Parameters <value 1-4> - Enter a value from 1 to 4 to identify the sFlow server
being configured here.
timeout <sec 1-2000000> - Used to specify the timeout for the
Analyzer server. When the server times out, all sFlow samples and
counter polls associated with this server will be deleted. The user