1
fwAlarmsFilterSet
1-173
Telnet Commands
fwAlarmsFilterSet
Show which alarms are enabled for Fabric Watch.
Syntax
fwAlarmsFilterSet [mode]
Availability Admin
Description Use this command to configure alarm filtering. By turning off the
alarms, all nonenvironment class alarms are suppressed. By turning
on the alarms, all class alarms are generated.
This command requires a Fabric Watch License.
Operand The following operand is optional:
Example
To enable Fabric Watch alarms:
switch:admin> fwAlarmsFilterSet
FW: Alarms are disabled
switch:admin> fwAlarmsFilterSet 1
FW: Alarms are enabled
See Also fwAlarmsFilterShow
mode
Specify 1 to enable the alarms, 0 to disable the alarms. If
no operand is specified, the default value is 0 (alarms are
deactivated). This operand is optional.