EMC DS-32B2 Switch User Manual


 
1
1-280
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
perfAddRWMonitor
Add a monitor for the SCSI Read and Write commands.
Syntax
perfAddRWMonitor [slotnumber/]portnumber[, "alias"]
Availability Admin
Description Use this command to define filter-based monitors to count the
number of SCSI FCP Read and Write commands in Fibre Channel
frames.
After a successful execution of this command, a monitor number is
displayed. The monitor number is provided for easy manipulation of
these filter-based performance monitors. The optional user defined
alias is also displayed if one was specified. All valid monitor
numbers and user-defined aliases can be retrieved with the
perfShowFilterMonitor command.
The maximum number of filters is eight per port including user
defined filters, read filters, write filters, and read/write filters.
Operands This command has the following operands:
slotnumber
Specify the slot number in an ED-12000B switch.
The slot number must be followed by a slash ( / )
and the port number.
The ED-12000B has a total of 10 slots counted
from 1 to 10. Slot number 5 and 6 are control
processor cards, and slot 1 through 4 and 7
through 10 are switch cards. On each switch card,
there are 16 ports counted from the bottom 0 to 15.
A particular port must be represented by both slot
number (1 through 4 or 7 through 10) and port
number (0 through 15).
This operand is not required for switches that do
not have blades.