EMC DS-32B2 Switch User Manual


 
1
1-390
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
sensorShow
Display sensor readings.
Syntax
sensorShow
Availability All users
Description Use this command to display the current temperature, fan and power
supply status and readings from sensors located on the switch. The
actual location of the sensors varies depending on the switch type.
In the ED-12000B, the information returned with
sensorShow is
specific to the logical switch you are logged in to:
If you are logged in to Logical switch 0, sensors 1 through 4 are
for switch blade slots 1 through 4, respectively. Sensors 5 and 6
are for the two CPs in slots 5 and 6, respectively.
If you are logged in to Logical switch 1, sensors 1 and 2 are for the
two CPs in slots 5 and 6, respectively. Sensors 3 through 6 are for
switch blade slots 7 through 10, respectively.
If you are logged in to the Active CP through the console port,
you are prompted to specify the logical switch this command is
executed on. If you log in to the Active CP through the Fabric OS
shell, this command always executes on the default switch
(logical switch 0).
Regardless of logical switch, sensors 7 through 9 are for the three
chassis fans, left to right, and sensors 10 through 13 are for the
four chassis power supplies, bottom to top.
Operands None