Example To view port statistics properties on port 1 on slot 8:
switch:admin> portstatsshow 8/1
stat_wtx 8657 4-byte words transmitted
stat_wrx 10118 4-byte words received
stat_ftx 557 Frames transmitted
stat_frx 566 Frames received
stat_c2_frx 0 Class 2 frames received
stat_c3_frx 2 Class 3 frames received
stat_lc_rx 284 Link control frames received
stat_mc_rx 1 Multicast frames received
stat_mc_to 0 Multicast timeouts
stat_mc_tx 0 Multicast frames transmitted
tim_rdy_pri 0 Time R_RDY high priority
tim_txcrd_z 1 Time BB_credit zero
er_enc_in 0 Encoding errors inside of frames
er_crc 0 Frames with CRC errors
er_trunc 0 Frames shorter than minimum
er_toolong 0 Frames longer than maximum
er_bad_eof 0 Frames with bad end-of-frame
er_enc_out 10 Encoding error outside of frames
er_disc_c3 0 Class 3 frames discarded
open 0 loop_open
transfer 0 loop_transfer
opened 0 FL_Port opened
starve_stop 0 tenancies stopped due to starvation
fl_tenancy 0 number of times FL has the tenancy
nl_tenancy 0 number of times NL has the tenancy
switch:admin>