EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
Since the test requires the operating system to operate, and the
operating system is loaded in the same memory, the test does not
and cannot test all 16 MB of the memory. Instead, it tests the
largest portion as given by the OS, which is typically about 13
MB.
Operand This command has the following operand:
Example
To run the RAM test on a switch:
switch:admin> ramTest
Running System DRAM Test ...... passed
Errors Listed below are possible error messages if failures are detected:
DIAG-MEMORY
DIAG-MEMSZ
DIAG-MEMNULL
See Also portRegTest
centralMemoryTest
cmiTest
sramRetentionTest
turboRamTest
camTest
statsTest
filterTest
portLoopbackTest
spinSilk
patternSize
Specify a number from 0 to 9 to determine the
number of patterns used for the data subtest.
The default value is 0 which runs all nine
patterns. A value from 1 to 9 will execute the
specified number of patterns. Any value over 9
is truncated to 9. Only the data subtest is
configurable. The address subtest is always
executed. This operand is optional.