EMC DS-32B2 Switch User Manual


 
1
1-446
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
status to DOWN. If two ports were faulty, then this contributor
would set the overall switch status to DOWN.
This command enables you to set a threshold for each contributor, so
that a certain number of failures are required to change the overall
status of the switch.
If the value of a policy parameter is set to 0, then this factor is not
used to determine the status of the switch. If the range of values for a
particular contributor are set to 0 for both MARGINAL and DOWN,
that contributor is not used in the calculation of the overall switch
status.
ISLStatus monitors ISLs that are part of a defined switch group. The
status of other ISLs on the same switch but outside of the group
definition will not be considered when calculating switch status. If no
switch groups are defined on this switch, then these ISLStatus
settings will have no effect on switch status.
The ISLStatus does not affect the status of the switch as quickly as the
other contributors. It may take a few minutes for a switch group ISL
status change to affect the state of the switch.
When PortStatus monitoring is set to values of (0,0), port status
changes are not logged to the event log and console. Similarly, GBIC
removal does not generate a message to the event log and console if
MissingGBICs
is set to (0,0). By configuring these options, the user
can more closely monitor for port status and/or removal of GBICs.
Operands
None