EMC DS-32B2 Switch User Manual


 
1
1-284
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
perfAddUserMonitor
Add a user-defined filter-based monitor.
Syntax
perfAddUserMonitor [slotnumber/]portnumber,
"grouplist"[,"alias"]
Availability Admin
Description Use this command to define a special mechanism to qualify frames
for statistics gathering to fit your own special need.
Each group of elements with the same offset will have their
comparison result (OR-ed) together before the combined result of
each group gets (AND-ed) together for final comparison result. If the
final result is logic 1, then the monitor counter will be increased by
one.
After a successful execution of this command, a monitor number is
displayed. The monitor number is provided for easy manipulation of
these filter-based performance monitors. The optional user-defined
alias is also displayed if one was specified. All valid monitor
numbers and user-defined aliases can be retrieved with the
perfShowFilterMonitor command.
The maximum number of filters is eight per port, including user
defined filters, read filters, write filters, and read/write filters. In
addition, there should be no more than six different offsets for each
port, and no more than four different values per Offset, user-defined.
This command requires a Performance Monitoring license.