EMC DS-32B2 Switch User Manual


 
1
1-182
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
fwFruCfg
Display or modify FRU state alert configuration.
Syntax
fwFruCfg
Availability Admin
Description Use this command to configure FRU states and actions. Based on
these configuration settings, Fabric Watch generates action when the
FRU state changes. To configure email alerts, use
fwMailCfg.
This command requires a Fabric Watch license.
Operands None
Example
To change FRU state alert configuration:
switch:admin> fwFruCfg
1 : Slot
2 : Power Supply
3 : Fan
4 : WWN
5 : Configure All
6 : Quit
Select an item => : (1..6) [6] 1
Alarm
Id Label Status State Action Freq TimeBase
=======================================================================
1 Slot #1 enable 48 17 5 Minute
2 Slot #2 enable 8 16 1 Minute
3 Slot #3 enable 16 16 1 Minute
4 Slot #4 enable 48 17 5 Minute
1 : change fru alarm state 5 : change fru status
2 : change fru alarm level 6 : apply fru configuration
3 : change alarm frequency 7 : cancel fru configuration changes
4 : change fru timebase 8 : return to previous page
Select Id => : (1..8) [8] 1
Enter Slot Number : (1..4) [4] 1
Absent-1, Inserted-2, Ready-4
Up-8, On-16, Off-32, Faulty-64
Enter fru alarm state => : (1..127) [48] 32
Id Label Status State Action Freq TimeBase
=======================================================================