Telnet Commands
perfAddWriteMonitor
Add a filter-based monitor for the SCSI Write command.
Syntax
perfAddWriteMonitor [slotnumber/]portnumber[, "alias"]
Availability Admin
Description Use this command to define filter-based monitors to count the
number of SCSI FCP Write commands in Fibre Channel frames.
After a successful execution of this command, a monitor number is
displayed. The monitor number is provided for easy manipulation of
these filter-based performance monitors. The optional user-defined
alias is also displayed if one was specified. All valid monitor
numbers and user-defined aliases can be retrieved with the
perfShowFilterMonitor command.
The maximum number of filters is eight per port, including
user-defined filters, read filters, write filters and read/write filters.
This command requires a Performance Monitoring license.
Operands This command has the following operands:
slotnumber
Specify the slot number in an ED-12000B switch. The
slot number must be followed by a slash ( / ) and the
port number.
The ED-12000B has a total of 10 slots counted from 1
to 10. Slot number 5 and 6 are control processor
cards, and slot 1 through 4 and 7 through 10 are
switch cards. On each switch card, there are 16 ports
counted from the bottom 0 to 15. A particular port
must be represented by both slot number (1 through
4 or 7 through 10) and port number (0 through 15).
This operand is not required for switches that do not
have blades.