1
1-438
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
The switch summary is followed by one line per port:
port number Port number. Valid values vary depending on the
switch type.
module type Port module type (GBIC or other):
◆ -- — no module present
◆ sw — shortwave laser
◆ lw — longwave laser
◆ cu — copper
◆ id — serial ID
port speed 1 G — 1 G per second fixed transfer speed
2 G — 2 G per second fixed transfer speed
N1 — 1 G per second negotiated transfer speed
N2 — 2 G per second negotiated transfer speed
AN— Auto negotiating
port state
◆ Port state information
◆ No_Card — no interface card present
◆ No_Module — no module (GBIC or other) present
◆ No_Light — module not receiving light
◆ No_Sync — module receiving light but out of sync
◆ In_Sync — module receiving light and in sync
◆ Laser_Flt — module signaling a laser fault
◆ Port_Flt — port marked faulty
◆ Diag_Flt — port failed diagnostics
◆ Lock_Ref — locking to the reference signal
◆ Testing — running diagnostics
◆ Online — port is up and running