EMC DS-32B2 Switch User Manual


 
1
1-422
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
statsTest
Run a statistics counter diagnostic test.
Syntax
statsTest [-passcnt passcount][-ports list]
Availability Admin
Description Use this command to verify the bloom statistics counter logic. It can
run on every base port of quadrant, and send the frame through
internal loopback with no CRC data to induce the CRC error. This
command is also called from
camtest.
This test covers following statistics counter functionality.
1. The number of received frames with CRC error that matched the
SID-DID pair specified in the LINK table. There are a total 16 of
these statistics counters (0-15), respectively.
2. The number of received words in frames that matched the
SID-DID pair specified in the LINK table. There are a total 16 of
these statistics counters (0-15), respectively.
3. The number of transmitted words in frames that matched the
SID-DID pair specified in the LINK table. There are a total 16 of
these statistics counters (0-15), respectively.
4. The number of frames with CRC error that matched the
corresponding ALI (0-127), respectively.
This command may not be executed on an operational switch. You
must first disable the switch using the
switchDisable command.
There is a LINK table that stores 16 pairs of SID-DID address. Each of the
SID-DID pair is named a LINK. This table is used for gathering statistics that
match the LINK.
Operands This command has the following operands:
passcount
Specify the number of times to perform this test.
The default value is 1. This operand is optional.
-ports list
Specify the port number(s) to perform this test.
All ports are set in default.