1
1-76
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
cmemRetentionTest
Run data retention test of the central memory SRAMs.
Syntax
cmemRetentionTest [passCount]
Availability Admin
Description Use this command to verify for data retention in the central memory
SRAMs in the ASIC.
This command may not be executed on an enabled switch. You must first
disable the switch using the switchDisable command.
Operand This command has the following operand:
Example
To run the data retention test on the central memory SRAMS:
switch:admin> cmemRetentionTest
Running CMEM Retention Test ... passed.
Errors Below are possible error messages if failures are detected:
DIAG-LCMRS
DIAG-LCMTO
DIAG-LCMEM
See Also camTest
centralMemoryTest
cmiTest
crossPortTest
portLoopbackTest
ramTest
spinSilk
sramRetentionTest
passCount
Specify the number of times to execute this
test. The default value is 1. This operand is
optional.