EMC DS-32B2 Switch User Manual


 
1
1-364
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
Example To display the basic set of statistics for blade 2, port 3:
switch:admin> portStatsShow 2/3
stat_wtx 1181994 4-byte words transmitted
stat_wrx 1188458 4-byte words received
stat_ftx 95830 Frames transmitted
stat_frx 15564 Frames received
stat_c2_frx 0 Class 2 frames received
stat_c3_frx 93 Class 3 frames received
stat_lc_rx 7735 Link control frames received
stat_mc_rx 0 Multicast frames received
stat_mc_to 0 Multicast timeouts
stat_mc_tx 0 Multicast frames transmitted
tim_rdy_pri 477 Time R_RDY high priority
tim_txcrd_z 0 Time BB_credit zero
er_enc_in 0 Encoding errors inside frames
er_crc 0 Frames with CRC errors
er_trunc 0 Frames shorter than minimum
er_toolong 0 Frames longer than maximum
er_bad_eof 0 Frames with bad end-of-frame
er_enc_out 3 Encoding error outside frames
er_disc_c3 0 Class 3 frames discarded
open 621461745 loop_open
transfer 621459041 loop_transfer
opened 621449530 FL_Port opened
starve_stop 0 tenancies stopped due to starvation
fl_tenancy 1023103300 number of times FL has the tenancy
nl_tenancy 1118689630 number of times NL has the tenancy
switch:admin>
See Also portErrShow
portShow