EMC DS-32B2 Switch User Manual


 
1
1-12
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
There are six communities and respective trap recipients supported
by the agent. The first three communities are for read-write access
(rw) and the last three are for read-only access (ro). Note that the
factory default value for the trap recipient of each community is
"0.0.0.0". The factory default values for the community strings are:
Community 1: Secret Code
Community 2: OrigEquipMfr
Community 3: private
Community 4: public
Community 5: common
Community 6: FibreChannel
In order for an SNMP Management Station to receive a trap generated by the
agent, the administrator must configure a trap recipient value to correspond
to the IP address of the Management Station.
There are six ACL (Access Control List) to restrict SNMP get/set
operations to hosts under a host-subnet-area. Host-subnet-area is
defined by comparing non-zero IP octets. For example, an ACL of
"192.168.64.0" enables access for any hosts that start with
"192.168.64.xx". An ACL check is turned off when all six entries
contain "0.0.0.0".
Operands None
Example
To modify the SNMP configuration values:
switch:admin> agtcfgSet
Customizing MIB-II system variables ...
At each prompt, do one of the following:
o <Return> to accept current value,
o enter the appropriate new value,
o <Control-D> to skip the rest of configuration, or
o <Control-C> to cancel any change.
To correct any input mistake:
<Backspace> erases the previous character,
<Control-U> erases the whole line,