EMC DS-32B2 Switch User Manual


 
1
1-274
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
After a successful execution of this command, a monitor number is
displayed. The monitor number is provided for easy manipulation of
these performance monitors.
This command requires a Performance Monitoring license.
Operands This command has the following operands:
slotnumber
Specify the slot number in an ED-12000B switch.
The slot number must be followed by a slash ( / )
and the port number.
The ED-12000B has a total of 10 slots counted from
1 to 10. Slot number 5 and 6 are control processor
cards, and slot 1 through 4 and 7 through 10 are
switch cards. On each switch card, there are 16
ports counted from the bottom 0 to 15. A
particular port must be represented by both slot
number (1 through 4 or 7 through 10) and port
number (0 through 15).
This operand is not required for switches that do
not have blades.
portnumber
Specify the port number where you want to add
an EE frame monitor. Valid values for the port
number vary depending on the switch type. This
operand is required.
SourceID
Specify the 3-byte SID (Source ID) of the
originator device. It should be in 0xDDAAPP
format, where DD is Domain ID, AA is Area ID,
and PP is ALPA ID. For example, 0x058e0f, has a
Domain ID of 5, an Area ID of 8e, and an ALPA ID
of f.
DestID
Specify the 3-byte DID (Destination ID) of the
destination device. It should be in 0xDDAAPP
format, where DD is Domain ID, AA is Area ID
and PP is ALPA ID. For example, 0x058e0f, has a
Domain ID of 5, an Area ID of 8e, and an ALPA ID
of f.