Force10 Networks S2410s Switch User Manual


 
SFTOS Command Reference for the S2410, Version 2.4.1.0 215
This section provides a detailed explanation of the Simple Network Time Protocol (SNTP)
commands. The commands are comprised of two functional groups:
Configuration Commands configure features and options of the switch.
Show commands display settings, statistics, and other information. For every
configuration command there is a show command that displays the configuration setting.
This chapter describes the following commands:
sntp broadcast client poll-interval
sntp client mode on page 216
sntp client port on page 216
sntp unicast client poll-interval on page 217
sntp unicast client poll-timeout on page 217
sntp unicast client poll-retry on page 217
sntp server on page 218
show sntp on page 218
show sntp client on page 219
show sntp server on page 220
sntp broadcast client poll-interval
This command sets the poll interval for SNTP broadcast clients in seconds as a power of two
where
poll-interval can be a value from 6 to 16.
Syntax
sntp broadcast client poll-interval poll-interval
Use the no sntp broadcast client poll-interval version of this command to reset the poll
interval for SNTP broadcast client back to its default value.
Default
6
Mode
Global Config
Chapter 11 SNTP Commands