Force10 Networks S2410s Switch User Manual


 
show sysinfo
SFTOS Command Reference for the S2410, Version 2.4.1.0 83
Example
Figure 17 show serviceport Command Output
Related
Commands
show sysinfo
This command displays switch information.
Syntax
show sysinfo
Table 11 Fields in Output of show serviceport
command
Field Description
IP Address The IP address of the Ethernet Management port.
The default value is 0.0.0.0
Subnet Mask The IP subnet mask for the Ethernet Management port.
The default value is 0.0.0.0
Default Gateway The default gateway for the Ethernet Management port.
The default value is 0.0.0.0.
ServPort Configured Protocol
Current
Indicates if the IP configuration of the Ethernet Management
port should be manually entered, or if it should be configured
through DHCP or Bootp. The default value is
none (manually
configured).
Burned In MAC Address The MAC address of the Ethernet Management port
Link Status Ethernet Management port link up or down
(Force10 S2410) #show serviceport
IP Address..................................... 10.11.197.177
Subnet Mask.................................... 255.255.0.0
Default Gateway................................ 10.11.197.190
ServPort Configured Protocol Current........... None
Burned In MAC Address.......................... 00:01:E8:99:99:9A
Link Status.................................... Up
serviceport ip Configures the IP configuration of the Ethernet Management port.
serviceport protocol Set the network configuration protocol to be used for configuring
access to the Ethernet Management port.
show interface
managementethernet
Displays the configuration of the management VLAN.