Force10 Networks S2410s Switch User Manual


 
show sntp client
SFTOS Command Reference for the S2410, Version 2.4.1.0 219
Field
Descriptions
Last Update Time—Time of last clock update
Last Attempt Time—Time of last transmit query (in unicast mode).
Last Attempt Status—Status of the last SNTP request (in unicast mode) or unsolicited message (in
broadcast mode).
Broadcast Count—Current number of unsolicited broadcast messages that have been received and
processed by the SNTP client since last reboot.
Multicast Count—Current number of unsolicited multicast messages that have been received and
processed by the SNTP client since last reboot
show sntp client
This command is used to display SNTP client settings.
Syntax
show sntp client
Mode
Privileged Exec
Example
Figure 48 show sntp client Command Example
Field
Descriptions
Client Supported Modes—Supported SNTP Modes (broadcast and/or unicast)
SNTP Version—The highest SNTP version the client supports
Port—SNTP Client Port
Client Mode—Configured SNTP Client Mode
Poll Interval—If enabled, the poll interval value for SNTP clients in seconds as a power of two
Poll Timeout—If enabled, the poll timeout value in seconds for SNTP clients
Poll Retry—If enabled, the poll retry value for SNTP clients
Force10# show sntp client
Client Supported Modes: unicast broadcast
SNTP Version: 4
Port: 123
Client Mode: disabled
Force10#