Panasonic A4 Series Power Supply User Manual


 
184
Parameter Setup
5D 0 to 1
<0>
–Input reversal of
torque command
You can reverse the polarity of the torque command input (SPR/TRQR :
CN X5, Pin-14 or CCWTL/TRQR : CN X5, Pin-16)
Direction of motor output torque
CCW direction (viewed from motor shaft) with (+) command
CW direction (viewed from motor shaft) with (+) command
Setup value
<0>
1
5C 10 to 100
<30>
0.1V/
100%
Input gain of
torque command
You can set the relation between the voltage applied to the torque
command input (SPR/TRQR : CN X5, Pin-14 or CCWTL/TRQR : CN X5,
Pin-16) and the motor output torque.
• Unit of the setup value is [0.1V/100%]
and set up input voltage necessary to
produce the rated torque.
• Default setup of 30 represents
3V/100%.
Rated
torque
torque
Default
command
input
voltage (V)
2
-2-4-6-8-10V
100
100
200
300[%]
200
300[%]
46810V
CW
CCW
5E 0 to 500
<500>
*2
%1st torque limit 
setup
You can limit the max torque for both CCW and CW direction with Pr5E.
Pr03 setup and Pr5F are ignored.
<Caution>
You cannot set up a larger value to this parameter than the default setup
value of "Max. output torque setup" of System parameter (which you
cannot change through operation with PANATERM
®
or panel). Default
value varies depending on the combination of the motor and the driver.
For details, refer to P.57, "Setup of Torque Limit " of Preparation.
• Setup value is to be given in
% against the rated torque.
• Right fig. shows example of
150% setup with Pr03=1.
• Pr5E limits the max. torque for
both CCW and CW directions.
This torque limit function limits the max. motor torque with the
parameter setup.
In normal operation, this driver permits approx. 3 times larger torque
than the rated torque instantaneously. If this 3 times bigger torque
causes any trouble to the load (machine) strength, you can use this
function to limit the max. torque.
speed
200
100
(Rated)
(Rating)
100
200
300
torque [%]
300(Max.)
(Max.)
CW
CCW
when Pr5E=150
Standard default : < >
PrNo.
Setup
range
UnitTitle Function/Content
<Notes>
• For parameters which default. has a suffix of "*2", value varies depending on the combination of the driver
and the motor.