Panasonic A4 Series Power Supply User Manual


 
342
Permissible Load at Output Shaft
50W, 100W
200W, 400W
750W
1kW
1.5kW to 3.0kW
4.0kW to 5.0kW
100W
200W, 400W
1.0kW to 2.0kW
3.0kW
4.0kW
5.0kW
500W to 1.5kW
2.0kW to 5.0kW
400W
1.5kW
2.5kW, 4.5kW
900W
2.0kW
3.0kW, 4.5kW
MSMD
MSMA
MQMA
MDMA
MHMA
MFMA
MGMA
Motor
series
Motor output
Radial thrust Radial thrust
Thrust load A
and B-direction
During runningAt assembly
Thrust load
A-direction B-direction
147
392
686
686
980
147
392
980
1666
980
1666
980
1862
980
1666
2058
88
147
294
392
588
88
147
588
784
588
784
588
686
588
784
980
117.6
196
392
490
686
117.6
196
686
980
686
980
686
980
1176
68.6
245
392
392
490
784
68.6
245
490
784
490
784
392
490
784
686
1176
1470
58.8
98
147
147
196
343
58.8
98
196
343
196
343
147
196
294
196
490
50W
100W
200W
400W
750W
MSMD
Motor
series
Motor
output
Formula of Load and
load point relation
P =
3533
L+39
Unit : N (1kgf=9.8N)
L
P
<Note>
When the load point varies, calculate the permissible radial
load, P (N) from the distance of the load point, L (mm) from
the mounting flange based on the formula of the right table,
and make it smaller than the calculated result.
P =
4905
L+59
P =
14945
L+46
P =
19723
L+65.5
P =
37044
L+77
L
L/2
P
A
M
B
Radial load (P) direction
Thrust load (A and B) direction