Panasonic A4 Series Power Supply User Manual


 
256
When in Trouble
Protective
function
Causes Measures
Error
code No.
Analog
input
excess
protection
39
Higher voltage has been applied to the analog
command input (SPR : CN X5, Pin-14) than the value
that has been set by Pr71 (Analog input excess setup)
This protective function is validated when SPR/TRQR/
SPL is valid such cases as, 
1)Velocity control 
when Pr02 (Control mode setup) is set to 1, 3 or 5 and
Pr05 (Velocity setup internal/external switching) is
set to 0 or 2, and when analog velocity command is
selected and speed zero clamp is invalidated. (veloc-
ity command is not zero).
2)Torque control 
when Pr02 (Control mode setup) is set to 2 or 4 and
Pr5B (Torque command selection) is set to 0. 3)Tor-
que control 
when Pr02 (Control mode setup) is set to 2, 4 or 5
andPr5B (Torque command selection) is set to 1,
and speed zero clamp is invalidated (Velocity com-
mand is not zero.)
• Set up Pr71 (Setup of analog input excess) correctly.
Check the connecting condition of the connector, CN
X5.
• Set up a larger value to Pr57 (Filter setup of Velocity
command).
• Set up Pr71 to 0 and invalidate the protective
function.
Absolute
system
down error
protection
40
Voltage of the built-in capacitor has fallen below the
specified value because the power supply or battery
for the 17-bit absolute encoder has been down.
After connecting the power supply for the battery, clear
the absolute encoder. (Refer to P.271, "Setup
(Initialization) of Absolute Encoder" of Supplement.)
You cannot clear the alarm unless you clear the
absolute encoder.
*Absolute
counter
over error
protection
41
Multi-turn counter of the 17-bit absolute encoder has
exceeded the specified value.
• Set up an appropriate value to Pr0B (Absolute
encoder setup) .
• Limit the travel from the machine origin within 32767
revolutions.
Absolute
over-speed
error
protection
42
The motor speed has exceeded the specified value
when only the supply from the battery has been
supplied to 17-bit encoder during the power failure.
• Check the supply voltage at the encoder side
(5V±5%)
• Check the connecting condition of the connector, CN
X6. 
• You cannot clear the alarm unless you clear the
absolute encoder.
*Absolute
single turn
counter
error
protection
44
Single turn counter error of 17-bit absolute encoder
has been detected.
Single turn counter error of 2500[P/r], 5-wire serial
encoder has been detected.
Replace the motor.
*Absolute
multi-turn
counter
error
protection
45
Multi turn counter error of 17-bit absolute encoder has
been detected.
Multi turn counter error of 2500[P/r], 5-wire serial
encoder has been detected.
Replace the motor.
Absolute
status error
protection
47
17-bit absolute encoder has been running at faster
speed than the specified value at power-on.
Arrange so as the motor does not run at power-on.
*Encoder 
Z-phase
error
protection
48
Missing pulse of Z-phase of 2500[P/r], 5-wire serial
encoder has been detected
The encoder might be a failure. Replace the motor.
*Encoder
CS signal
error
protection
49
CS signal logic error of 2500[P/r], 5-wire serial encoder
has been detected
The encoder might be a failure. Replace the motor.