Panasonic A4 Series Power Supply User Manual


 
212
Parameter Setup
Parameters for Auto-Gain Tuning
20
0 to 10000
<250>*
%Inertia ratio
You can set up the ratio of the load inertia against the rotor (of the motor) inertia.
When you execute the normal auto-gain tuning, the load inertial will be
automatically estimated after the preset action, and this result will be
reflected in this parameter.
The inertia ratio will be estimated at all time while the real-time auto-gain
tuning is valid, and its result will be saved to EEPROM every 30 min.
<Caution>
If the inertia ratio is correctly set, the setup unit of Pr11 and Pr19
becomes (Hz). When the inertia ratio of Pr20 is larger than the actual, the
setup unit of the velocity loop gain becomes larger, and when the inertia
ratio of Pr20 is smaller than the actual, the setup unit of the velocity loop
gain becomes smaller.
Pr20=(load inertia/rotor inertia) X 100 [%]
21 0 to 7
<1>
–Setup of real-time
auto-gain tuning
You can set up the action mode of the real-time auto-gain tuning.
With higher setup such as 3 or 6, the driver respond quickly to the change
of the inertia during operation, however it might cause an unstable
operation. Use 1 or 4 for normal operation.For the vertical axis application,
use with the setup of 4 to 6.
When vibration occurs at gain switching, set up this to "7".
Setup value
0
<1>
2
3
4
5
6
7
Real-time
auto-gain tuning
Invalid
Normal mode
Vertical axis mode
No gain switching
Varying degree of 
load inertia in motion
Little change
Gradual change
Rapid change
Little change
Gradual change
Rapid change
Little change
Standard default : < >
PrNo.
Setup
range
UnitTitle Function/Content
1D
100 to 1500
<1500>
Hz1st notch
frequency
You can set up the frequency of the 1st resonance suppressing notch filter.
The notch filter function will be invalidated by setting up this parameter to
"1500".
1E 0 to 4
<2>
–1st notch width
selection
You can set up the notch filter width of the 1st resonance suppressing filter in 5 steps.
Higher the setup, larger the notch width you can obtain.
Use with default setup in normal operation.
18
19
1A
1B
1C
0 to 3000
A to C-frame:<73>*
D to F-frame:<38>*
1 to 3500
A to C-frame:<35>*
D to F-frame:<18>*
1 to 1000
<1000>*
0 to 5
<0>*
0 to 2500
A to C-frame:<65>*
D to F-frame:<126>*
1/s
Hz
ms
–
0.01ms
2nd gain of
position loop
2nd gain of velocity
loop 
2nd time constant of
velocity loop integration
2nd filter of velocity
detection
2nd time constant
of torque filter
Position loop, velocity loop, speed detection filter and torque command
filter have their 2 pairs of gain or time constant (1st and 2nd).
For details of switching the 1st and the 2nd gain or the time constant, refer
to P.226, "Adjustment".
The function and the content of each parameter is as same as that of the
1st gain and time constant.
Standard default : < >
PrNo.
Setup
range
UnitTitle Function/Content