Setup of Parameter and Mode
Parameters for Auto-Gain Tuning
Parameters for Adjustment (2nd Gain Switching Function)
* In this documentation, each mode is represented by the following symbols
P : Position control, S : Velocity control, T : Torque control, F : Full-closed control, P/S : Position (1st),/
Velocity (2nd) control, P/T : Position (1st)/Torque (2nd) control, S/T : Velocity (1st)/Torque (2nd) control
For parameters which default values are parenthesized by "< >", default value varies automatically by the
real-time auto-gain tuning function. Set up Pr21 (Setup of Real-time auto-gain tuning mode) to 0 (invalid)
when you want to adjust manually.
Set up of parameter Range Unit Related Control Mode
Parameter No.
(Pr )
Default
A to C-frame D to F-frame
20
21
22
23
24
25
26
2F *3
0 to 10000
0 to 7
0 to 15
0 to 2
0 to 2
0 to 7
0 to 1000
0 to 64
<250>
1
4 1
1
0
0
10
0
%
–
–
–
–
–
0.1rev
–
All
All
All
P, S, F
P, F
All
P, F
P, S, F
Inertia ratio
Setup of real-time auto-gain tuning mode
Mechanical stiffness at real-time auto-gain tuning
Setup of adaptive filter mode
Selection of damping filter switching
Setup of action at normal mode auto-gain tuning
Setup of software limit
Adaptive filter frequency
Set up of parameter Range Unit Related Control Mode
Parameter No.
(Pr )
Default
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
0 to 1
0 to 10
0 to 10000
0 to 20000
0 to 20000
0 to 10000
0 to 5
0 to 10000
0 to 20000
0 to 20000
–
–
–
0 to 500
–
–
<1>
<0>
<30>
<50>
<33>
<20>
<0>
0
0
0
–
–
–
300
–
–
–
–
166µS
–
–
–
166µS
–
–
–
–
–
r/min
–
–
All
All
All
All
All
P, F
S, T
S, T
S, T
S, T
–
–
–
All
–
–
Setup of 2nd gain
1st mode of control switching
1st delay time of control switching
1st level of control switching
1st hysteresis of control switching
Time for position gain switching
2nd mode of control switching
2nd delay time of control switching
2nd level of control switching
2nd hysteresis of control switching
(For manufacturer's use)
(For manufacturer's use)
(For manufacturer's use)
Setup of JOG speed
(For manufacturer's use)
(For manufacturer's use)
(1+setup value)
x 166µs
*3 this parameter will be automatically set up when the adaptive filter is validated (Pr23, “Setup of adaptive
filter mode” is “1”, and you cannot set this up at your discretion. Set up Pr23, “Setup of adaptive filter
mode” to “0” (invalid) to clear this parameter.