Panasonic A4 Series Power Supply User Manual


 
309
[Supplement]
Supplement
Power Supply
100V type : Single phase, 100V
+10%
to 115V
+10%
50/60Hz
(A, B and C-frame)
–15% –15%
200V type : Single phase, 200V
+10%
to 240V
+10%
50/60Hz
(B, C-frame)
–15% –15%
200V type : Single/3-phase, 200V
+10%
to 240V
+10%
50/60Hz
(C, D-frame)
–15% –15%
200V type : 3-phase, 200V
+10%
to 230V
+10%
50/60Hz
(E, F-frame)
–15% –15%
(1) This product is designed to be used at over-voltage category (Installation category) II of EN 50178:1997.
If you want to use this product un over-voltage category (Installation category) III, install a surge ab-
sorber which complies with EN61634-11:2002 or other relevant standards at the power input portion.
(2) Use an insulated power supply of DC12 to 24V which has CE marking or complies with EN60950
Circuit Breaker
Install a circuit breaker which complies with IEC Standards and UL recognizes (Listed and marked)
between power supply and noise filter.
Noise Filter
When you install one noise filter at the power supply for multi-axes application, contact to a manufacture of
the noise filter.
Option part No. 
DV0P4170
Single phase 100V/200V
Applicable driver (frame)
A and B-frame
Manufacturer's part No.
SUP-EK5-ER-6
Manufacturer
Okaya Electric Ind.
ABCDEFGH
115
DV0P4180
105 95 70 43 10 52 5.5
145
DV0P4220
135 125 70 50 10 52 5.5
K
M4
M4
L
M4
M4
Label
Label
A
B
C
H
10
F
E
D
G
Earth terminal
M4
M4
Screw for cover
M3
Cover
Body
Terminal cover 
(transparent)
2 – ø4.5
R
Cx Cx
Cy
LL
Cy
2 – ø4.5 x 6.75
53.1±1.0
100.0 ± 2.0
88.0
75.0
5.0
12.0
10.0
50.0
60.0
7.0
2.0
(11.6)
(13.0
)
6 – M4
2
1
3
4
Circuit diagram
4
5
1
2
63
Circuit diagram
L1
Cx1
IN OUT
IN OUT
R Cx1
Cy1
Option part No.
DV0P4180
DV0P4220
3-phase 200V
Applicable driver (frame)
C-frame
D and E-frame
Manufacturer's part No.
3SUP-HQ10-ER-6
3SUP-HU30-ER-6
Manufacturer
Okaya Electric Ind.
Voltage specifications 
for driver
Voltage specifications 
for driver