Panasonic A4 Series Power Supply User Manual


 
37
[Preparation]
Preparation
In Case of 3-Phase, 200V (E and F-frame)
Red
White
Black
Green
PIN No. Application
PIN No. Application
[Motor portion] 
Connector : by Japan Aviation Electronics Ind.
A
B
D
C
AHG
CDE
BIF
CBA
IHG
FED
A
JL04V-2E20-4PE-B-R
JL04HV-2E22-22PE-B-R
JL04V-2E20-18PE-B-R
JL04V-2E24-11PE-B-R
U-phase
V-phase
W-phase
Ground
PIN No.
B
C
D
Application
G
H
A
F
I
B
E
D
C
Brake
Brake
NC
U-phase
V-phase
W-phase
Ground
Ground
NC
A Brake
Brake
NC
U-phase
V-phase
W-phase
Ground
Ground
NC
B
C
D
E
F
G
H
I
Motor
ALM
37
ALM+
L2
L3
r
t
P
MC
MC
NFB
ALM
ON
OFF
B1
B2
U
V
W
L1
Surge absorber
ALM–
DC12 to 24V
(±5%)
(Remove the short wire when you connect 
the external regenerative resistor.)
36
L
<Remark> Do not connect anything to NC.
Power supply 3-phase, 200V to 230V
+10%
–15%
+10%
–15%
Noise
filter
Main power
supply
Control power
supply
Motor
connection
External regenerative resistor
MC
Built-in thermostat of an external
regenerative resistor (light yellow)
How to
connect
Attach the handle lever to the
handling slot on the upper
portion. Press down the lever
to push down the spring.
Insert the peeled cable
while pressing down the
lever, until it hits the
insertion slot (round hole).
Release the lever.
• Follow the procedures below for the wiring connection to the Connector CN X1 and X2 .
1. Peel off the insulation cover of the cable.
(see the right fig for exact length for peeling.)
2. Insert the cable to the connecter in the following 2 methods. 
(a) Using the attached Handle Lever 
(b) Using a screw driver (blade width of 3.0 to 3.5 mm)
8 to 9mm
Wiring method to connector (A to D-frame)
Press the screw driver to
the handling slot on the
upper portion to push
down the spring.
Insert the peeled cable
while pressing down the
screw driver, until it hits the
insertion slot (round hole).
Release the screw driver
.
* You can pull out the cable by pushing down the spring as the above.
* You can pull out the cable by pushing down the spring as the above.
<CAUTION> 
Peel off the cable with
exact length (8 to 9 mm).
Take off the connector
from the Servo Driver
before making
connection. 
Insert one cable into each
one of cable insertion
slot. 
Pay attention to injury by
screw driver.
(a) Using handle lever
(b) Using screw driver
1 2 3
1 2 3